Search results

  1. Gamma Tech

    Gamma X-ELS button

    You can order a new tension button through me. email me at john.matechen@gammasports.com with your phone number.
  2. Gamma Tech

    gamma II drop weight test and adjusment

    A drop weight machine will not need calibrated, ever. The physics used will always produce a consistent result. As long as the drop weight bar is parallel to the floor whatever the weight is aligned to on the bar, that is what the tension will be. Even is the bar is up or down a few degrees...
  3. Gamma Tech

    Is the Diablo/gripper too far below the string bed?

    You can add the spacer to the machine to get the tensioner a little higher but you really do not need to do that. The reason the diablo/roller guide is there is to provide a consistent angle of the string to the gripper jaws. As you string a racquet you will notice that as you get closer to the...
  4. Gamma Tech

    The weight of the weight in a drop weight Gamma

    If you still need the weight for the drop weight machine I can help you with that. Our retail partners will not stock that part. Since they represent several manufacturers it is not possible for them to carry all parts for all machines. They only stock the accessories that are used regularly...
  5. Gamma Tech

    Curved vs straight clamp base tracks?

    The main reason Gamma Sports went to a curved slot was simply to allow the base clamps to move a bit farther apart providing a little more "reach" when string some of today's racquet geometries.
  6. Gamma Tech

    Help, screw fell off Gamma six-point machine, have no clue where from

    HI Anfield. The screw that you show is a shoulder support lock knob. It screws up from underneath the mounting arm and into the shoulder support. There's one for each of the four shoulder supports. I can help you order replacements if needed. They are not expensive. You can email me at...
  7. Gamma Tech

    Clamps moving a lot

    In my previous response I mentioned tightening the 17mm lock nut to adjust the base clamp, however after seeing your video you have a very early model Progression machine. The base clamps on that machine have been out of production for several years and the base clamps are no longer available...
  8. Gamma Tech

    Clamps moving a lot

    It sounds like the base clamp probably just need adjusted. Never, never, never, remove the base clamp lever and try to adjust the clamp from the top, teh sadjustment should be made from underneath. Leave the base clamp on the turntable and look under your turntable and you will see holes about...
  9. Gamma Tech

    What is the maintenance difference of different machines?

    From a machine tech's point of view.....if it ain't broke don't fix it. Best thing you can do is just clean string clamp and gripper surfaces, keep dust off the machine, and check calibration every once in a while (couple times a year or after 40-50 racquets). The "maintenance" issues I get...
  10. Gamma Tech

    Tighten clamp base on Gamme 6900els

    The 17mm lock nut has a nylon insert that helps secure the threads. It sounds like the nylon insert has broken down and is no longer providing friction between the threads. I can send you a replacement.
  11. Gamma Tech

    Gamma Progression X-Es tension knob getting tuff to turn.

    The tension adjustment knob has a long threaded rod (about 6" long) that has a square metal block that rides back and forth on it as you adjust tension up or down. Over time the lubricant may get dirty, dry, and gummy and clog the threads making the adjustment knob difficult to turn. If you...
  12. Gamma Tech

    Gamma clamp clicking sound...

    myke232, Hummmmm not sure what the clicking is, but we'll figure it out. If you can email me a short video I might see/hear what the problem is. Send the video to cad@gammasports.com Once we know what the problem is, we'll post back here.
  13. Gamma Tech

    Problem with my new gamma drop weight...

    claudiacardoso, Can you post a photo of the spot where you are hearing the clang?
  14. Gamma Tech

    Gamma Support Post Protect Pads

    I can help you with parts for Gamma machines that you can not find on line. e mail me at cad@gammasports.com
  15. Gamma Tech

    Gamma x-2 uneven posts

    Sorry, but I have not seen your emails with the problem with the X-2 mounting stands. The problem could be that there are burrs protruding from the hole that were drilled and tapped for the set screws that secure the stands. That would explain the reason they are not straight. email me at...
  16. Gamma Tech

    Missing piece on Gamma Progression 602

    That's an older version of the 602 but I can help you with the missing rubber tip. email me your contact info at cad@gammasports.com
  17. Gamma Tech

    Gamma 5800 ELS calibration

    Hi Chris, If you email me at cad@gammasports.com I can provide you the answers you are looking for in detail.
  18. Gamma Tech

    Gamma 6400

    Call Gamma sports and ask for me.
  19. Gamma Tech

    Gamma 5800 ELS calibration

    Any of the current Gamma clamps will fit into the base clamps on the 5800. The clamp with the widest gripper jaw is the Black metal composite clamp.
  20. Gamma Tech

    To Gamma Tech...Need gripper schematic diagram

    Ricardo, email me at cad@gammasports.com with your phone number
  21. Gamma Tech

    Gamma starting clamps trouble

    The best glue to bond a lose plate back onto a starting clamp, string clamp, or gripper is Loctite 330. It's a two part system that includes a adhesive gel and a spray activator. The adhesive is placed on one surface, spray the other surface, and when they come together the bond occurs. Works...
  22. Gamma Tech

    How to store Gamma X-6FC with cover?

    Sorry I'm just now posting. On the back side of the gripper drum there is a cap screw that keeps the DW bar from rotating too far forward and possibly banging into a racquet when mounted. When covering the machine, back out the screw so that the DW bar will lay all the way over on top of the...
  23. Gamma Tech

    How to store Gamma X-6FC with cover?

    The correct cover for the X-6FC is the MGSMC cover, not the MPMC. Best way to position the DW bar is up over the rotational gripper. Let me know if you have any additional questions.
  24. Gamma Tech

    Stringing with the Gamma X-2/Progression 200

    Keep in mind that the diamond dust coating is real diamond, so it’s really hard. The grinding stone is softer than the diamond so it will be consumed as you rub the surface. Alcohol and a brush is great for removing some build up and I always recommend using that method. However, for stubborn...
  25. Gamma Tech

    How to get a tighter string job

    wow...perhaps try using a cast iron frying pan.
  26. Gamma Tech

    gamma progression II FC/drop weight

    It is not possible to add the manual spring winder tensioner to the Progression drop weight machine. These are two completely different types of machines and the foot print of the base on the drop weight machines is not big enough to accept the support post, winder bar of the Progression ST II.
  27. Gamma Tech

    help with Gamma 790 ELS

    Red001 Yep....you're right! Evidently I know a lot about machines but can't read. Lol
  28. Gamma Tech

    help with Gamma 790 ELS

    Red001 When going from a standard turntable to a self-centering turntable the reason the two are not interchangeable is due to the self-centering assembly inside turntable that moves both mounting stands at the same time. There is a long threaded rod running down the center of the turntable with...
  29. Gamma Tech

    Gamma x-2 stringer, string gripper

    The gripper plates in the rotational gripper have a diamond dust coating that provides the friction to hold the string. It should not leave marks on the string. Over time string dust and debris can build up on the plates and can lead to string slipping or marking. Try cleaning the plates by...
Top